Eaton T3-4-8344/I2/SVB-SW Surface Mounting Main Switch Moeller Series T3 Main switch
Brand: Eaton | Model: T3-4-8344/I2/SVB-SW | Condition: New | NEO SKU: 11263-2
Original price was: $159.42.$131.30Current price is: $131.30.
2 in stock
Free Shipping on orders over $50.
*(Domestic only)
Need it fast? Next Day Air available at check out.
Same Day Handling on orders prior to 2pm Eastern Monday – Friday
2 in stock
NEO SKU: 11263-2 | Category: Disconnectors & Load Switches
Product Details for New:
Product Details for Eaton T3-4-8344/I2/SVB-SW Surface Mounting Main Switch Moeller Series T3 Main switch:
Condition: New
Brand: Eaton
Model: T3-4-8344/I2/SVB-SW
EAN: 4015082072131
Country of Origin: Germany
Only logged in customers who have purchased this product may leave a review.
Eaton T3-4-8344/I2/SVB-SW Surface Mounting Main Switch Moeller Series T3 Main switch
Specifications:
SKU: 11263-2
Condition: New Surplus Manufacturer Packaging
Brand: Eaton
Model: T3-4-8344/I2/SVB-SW
Description: Surface Mounting Main Switch Moeller Series T3 Main switch
Origin: Germany
EAN: 4015082072131
Notes: From MFG:
Certifications
IEC/EN 60947
UL File No.: E36332
CE
CSA-C22.2 No. 94
UL Category Control No.: NLRV
VDE 0660
CSA Class No.: 3211-05
CSA File No.: 012528
IEC/EN 60947-3
CSA
UL 60947-4-1
UL
IEC/EN 60204
CSA-C22.2 No. 60947-4-1-14
Product Tradename
T3
Product Type
Main switch
Product Sub Type
None
Catalog Notes
Rated Short-time Withstand Current (Icw) for a time of 1 second
Features & Functions
Features
Version as maintenance-/service switch
Version as main switch
Fitted with:
Black rotary handle and locking ring
Functions
STOP function
Interlockable
Locking facility
Lockable in the 0 (Off) position
Number of poles
8
General information
Degree of protection
NEMA 12
Degree of protection (front side)
IP65
Lifespan, mechanical
500,000 Operations
Mounting method
Surface mounting
Mounting position
As required
Number of contact units
4
Operating frequency
1200 Operations/h
Overvoltage category
III
Pollution degree
3
Rated impulse withstand voltage (Uimp)
6000 V AC
Safe isolation
440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)
B10d values as per EN ISO 13849-1, table C.1
Shock resistance
12 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable for
Branch circuits, suitable as motor disconnect, (UL/CSA)
Ground mounting
Switching angle
90 °
Climatic environmental conditions
Ambient operating temperature – min
-25 °C
Ambient operating temperature – max
40 °C
Ambient operating temperature (enclosed) – min
-25 °C
Ambient operating temperature (enclosed) – max
40 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
Terminal capacity
2 x (1 – 6) mm², solid or stranded
1 x (0.75 – 4) mm², flexible with ferrules to DIN 46228
2 x (0.75 – 4) mm², flexible with ferrules to DIN 46228
1 x (1 – 6) mm², solid or stranded
Screw size
M4, Terminal screw
Tightening torque
1.6 Nm, Screw terminals
17.7 lb-in, Screw terminals
Electrical rating
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)
260 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)
260 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)
240 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)
170 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
23.7 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
23.7 A
Rated operational current (Ie) at AC-3, 500 V
23.7 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
14.7 A
Rated operational current (Ie) at AC-21, 440 V
32 A
Rated operational current (Ie) at AC-23A, 230 V
32 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V
32 A
Rated operational current (Ie) at AC-23A, 500 V
26.4 A
Rated operational current (Ie) at AC-23A, 690 V
17 A
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms
25 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms
20 A
Rated operational current (Ie) at DC-21, 240 V
1 A
Rated operational current (Ie) at DC-23A, 24 V
25 A
Rated operational current (Ie) at DC-23A, 48 V
25 A
Rated operational current (Ie) at DC-23A, 60 V
25 A
Rated operational current (Ie) at DC-23A, 120 V
12 A
Rated operational current (Ie) at DC-23A, 240 V
5 A
Rated operational current (Ie) star-delta at AC-3, 220/230 V
32 A
Rated operational current (Ie) star-delta at AC-3, 380/400 V
32 A
Rated operational current (Ie) star-delta at AC-3, 500 V
32 A
Rated operational current (Ie) star-delta at AC-3, 690 V
25.5 A
Rated operational power at AC-3, 380/400 V, 50 Hz
11 kW
Rated operational power at AC-3, 415 V, 50 Hz
11 kW
Rated operational power at AC-3, 500 V, 50 Hz
15 kW
Rated operational power at AC-3, 690 V, 50 Hz
11 kW
Rated operational power at AC-23A, 220/230 V, 50 Hz
7.5 kW
Rated operational power at AC-23A, 400 V, 50 Hz
15 kW
Rated operational power at AC-23A, 500 V, 50 Hz
15 kW
Rated operational power at AC-23A, 690 V, 50 Hz
15 kW
Rated operational power star-delta at 220/230 V, 50 Hz
7.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz
15 kW
Rated operational power star-delta at 500 V, 50 Hz
18.5 kW
Rated operational power star-delta at 690 V, 50 Hz
22 kW
Rated operational voltage (Ue) at AC – min
690 V
Rated operational voltage (Ue) at AC – max
690 V
Rated uninterrupted current (Iu)
32 A
Uninterrupted current
Rated uninterrupted current Iu is specified for max. cross-section.
Short-circuit rating
Rated conditional short-circuit current (Iq)
1 kA
Rated short-time withstand current (Icw)
0.65 kA
650 A, Contacts, 1 second
Short-circuit protection rating
35 A gG/gL, Fuse, Contacts
Switching capacity
Load rating
1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
2 x Iₑ (with intermittent operation class 12, 25 % duty factor)
Number of contacts in series at DC-21A, 240 V
1
Number of contacts in series at DC-23A, 24 V
1
Number of contacts in series at DC-23A, 48 V
2
Number of contacts in series at DC-23A, 60 V
3
Number of contacts in series at DC-23A, 120 V
3
Number of contacts in series at DC-23A, 240 V
5
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)
320 A
Voltage per contact pair in series
60 V
Contacts
Control circuit reliability
1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Actuator
Actuator color
Black
Actuator type
Door coupling rotary drive
Design verification
Equipment heat dissipation, current-dependent Pvid
1.1 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.1 W
Rated operational current for specified heat dissipation (In)
32 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard’s requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
UV resistance only in connection with protective shield.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard’s requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
TECHNICAL DATA ETIM 8.0
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector (ecl@ss10.0.1-27-37-14-03 [AKF060013])
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as emergency stop installation
No
Version as reversing switch
No
Number of switches
1
Max. rated operation voltage Ue AC
690 V
Rated operating voltage
690 – 690 V
Rated permanent current Iu
32 A
Rated permanent current at AC-23, 400 V
32 A
Rated permanent current at AC-21, 400 V
32 A
Rated operation power at AC-3, 400 V
11 kW
Rated short-time withstand current lcw
0.65 kA
Rated operation power at AC-23, 400 V
15 kW
Switching power at 400 V
15 kW
Conditioned rated short-circuit current Iq
1 kA
Number of poles
8
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Device construction
Complete device in housing
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Colour control element
Black
Type of control element
Door coupling rotary drive
Interlockable
Yes
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
*Actual product may vary from images.*
NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with Eaton or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.
We do our best to get all the information in this listing correct. If you see an error or have any questions, please contact us.
Additional information
Weight | 6 lbs |
---|---|
Dimensions | 11 × 11 × 11 in |
Brand | Eaton |
Model | T3-4-8344/I2/SVB-SW |
Origin | Germany |
Condition | New |
EAN | 4015082072131 |
Body Notes | 000 switching operations statistically determined, 1 second Short-circuit protection rating 35 A gG/gL, 120 V 12 A Rated operational current (Ie) at DC-23A, 120 V 3 Number of contacts in series at DC-23A, 220 V, 220/230 V, 220/230 V 32 A Rated operational current (Ie) star-delta at AC-3, 230 V, 230 V 32 A Rated operational current (Ie) at AC-23A, 24 V 1 Number of contacts in series at DC-23A, 24 V 25 A Rated operational current (Ie) at DC-23A, 240 V 1 A Rated operational current (Ie) at DC-23A, 240 V 1 Number of contacts in series at DC-23A, 240 V 23.7 A Rated operational current (Ie) at AC-3, 240 V 5 A Rated operational current (Ie) star-delta at AC-3, 240 V 5 Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3) 320 A Voltage per contact pair in series 60 V Contacts Control circuit reliability 1 failure per 100, 25 % duty factor) Number of contacts in series at DC-21A, 380 V, 380/400 V, 380/400 V 32 A Rated operational current (Ie) star-delta at AC-3, 40 % duty factor) 2 x Iₑ (with intermittent operation class 12, 400 V, 400 V 11 kW Rated short-time withstand current lcw 0.65 kA Rated operation power at AC-23, 400 V 32 A Rated operation power at AC-3, 400 V 32 A Rated permanent current at AC-21, 415 V, 415 V 23.7 A Rated operational current (Ie) at AC-3, 415 V 32 A Rated operational current (Ie) at AC-23A, 440 V 32 A Rated operational current (Ie) at AC-23A, 48 V 2 Number of contacts in series at DC-23A, 48 V 25 A Rated operational current (Ie) at DC-23A, 50 Hz 11 kW Rated operational power at AC-23A, 50 Hz 11 kW Rated operational power at AC-3, 50 Hz 15 kW Rated operational power at AC-23A, 50 Hz 15 kW Rated operational power at AC-3, 50 Hz 15 kW Rated operational power star-delta at 220/230 V, 50 Hz 15 kW Rated operational power star-delta at 500 V, 50 Hz 18.5 kW Rated operational power star-delta at 690 V, 50 Hz 7.5 kW Rated operational power at AC-23A, 50 Hz 7.5 kW Rated operational power star-delta at 380/400 V, 500 V, 500 V 23.7 A Rated operational current (Ie) at AC-3, 500 V 26.4 A Rated operational current (Ie) at AC-23A, 500 V 32 A Rated operational current (Ie) star-delta at AC-3, 60 % duty factor) 1.6 x Iₑ (with intermittent operation class 12, 60 V 25 A Rated operational current (Ie) at DC-23A, 60 V 3 Number of contacts in series at DC-23A, 660 V, 690 V, 690 V 14.7 A Rated operational current (Ie) at AC-21, 690 V 17 A Rated operational current (Ie) at DC-1, 690 V 25.5 A Rated operational power at AC-3, According to EN 61140 Safety parameter (EN ISO 13849-1) B10d values as per EN ISO 13849-1, According to IEC/EN 60068-2-27, at 24 V DC, automation, Between the contacts, circuit breaker, constant, Contacts, Contacts Switching capacity Load rating 1.3 x Iₑ (with intermittent operation class 12, control switches L/R = 50 ms 20 A Rated operational current (Ie) at DC-21, current-dependent Pvid 1.1 W Heat dissipation capacity Pdiss 0 W Heat dissipation per pole, current-dependent Pvid 1.1 W Rated operational current for specified heat dissipation (In) 32 A Static heat dissipation, cyclic, flexible with ferrules to DIN 46228 1 x (1 – 6) mm², flexible with ferrules to DIN 46228 2 x (0.75 – 4) mm², front side IP65 Degree of protection (NEMA) 12, Fuse, Half-sinusoidal shock 20 ms Suitable for Branch circuits, load-break switches l/r = 1 ms 25 A Rated operational current (Ie) at DC-13, Mechanical, mechanical 500, process control engineering / Low-voltage switch technology / Off-load switch, provided the information in the instruction leaflet (IL) is observed. TECHNICAL DATA ETIM 8.0 Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) Electric engineering, Screw terminals 17.7 lb-in, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of assemblies Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, solid or stranded 1 x (0.75 – 4) mm², solid or stranded Screw size M4, suitable as motor disconnect, table C.1 Shock resistance 12 g, Terminal screw Tightening torque 1.6 Nm, to IEC 60068-2-30 Damp heat, to IEC 60068-2-78 Terminal capacities Terminal capacity 2 x (1 – 6) mm² |
Related Products
FAQ’s
Looking for a replacement Eaton T3-4-8344/I2/SVB-SW with fast shipping?
NEO Surplus will ship in stock items the same day if purchased by 2pm ET, Monday – Friday.
Can I ship using my carrier account?
Do you offer Blind Shipping?
Other Questions?
Contact us if you have more queNEO Surplus is not an authorized distributor, representative, reseller, or affiliated with Eaton or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.
NEO Surplus buys surplus MRO items and then resells them on the secondary parts markets.
We do our best to get all the information in this listing correct. If you have any questions or see an error, please contact us.
Reviews
There are no reviews yet.
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.