Telemecanique ATV21HD15N4 Variable Speed Drive 15kW 20HP V1.8 IE04

Brand: Telemecanique | Model: ATV21HD15N4 | Condition: Used | NEO SKU: 11527-6

Out of stock

Request for Quote

We are currently out of stock on this item but let us know how many you need, condition, how soon, and a budget and we will get to work for you ASAP!
Request For Quote

NEO SKU: 11527-6 | Category: Variable Frequency Drives

Telemecanique ATV21HD15N4 Variable Speed Drive 15kW 20HP V1.8 IE04

Product Details:

Condition: Used

Capacity: 15kW 20HP

Country of Origin: Indonesia

Electrical

Additional information

Weight25 lbs
Dimensions16 × 16 × 16 in
Brand

Telemecanique

Model

ATV21HD15N4

Capacity

15kW 20HP

Origin

Indonesia

Condition

Used

UPC

785901701194

Telemecanique ATV21HD15N4 Variable Speed Drive 15kW 20HP V1.8 IE04

Specifications:

SKU: 11527-6
Condition: Used
Brand: Telemecanique
Model: ATV21HD15N4
Description: Variable Speed Drive V1.8 IE04

Capacity: 15kW 20HP
Origin: Indonesia
UPC: 785901701194

Notes: From MFG:

Range of Product
Altivar 21
Product or Component Type
Variable speed drive
Product destination
Asynchronous motors
Product Specific Application
Pumps and fans in HVAC
Assembly style
With heat sink
Component name
ATV21
EMC filter
Class A EMC filter integrated
power supply voltage
380…480 V – 15…10 %
Phase
3 phase
Motor power kW
15 kW
Maximum Horse Power Rating
20 hp
Line current
22.8 A 480 V
28.5 A 380 V
Speed range
1…10
Transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
Asynchronous motor control profile
Constant voltage/frequency ratio
Quadratic voltage/frequency ratio
Constant voltage/frequency ratio with automatic IR compensation
Energy saving ratio
Current flux vector control (FVC) without speed feedback
Communication Port Protocol
Modbus
Type of polarization
No impedance
IP degree of protection
IP20 on upper part without blanking plate on cover EN/IEC 60529
IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1
IP21 EN/IEC 60529
IP21 EN/IEC 61800-5-1
IP41 on upper part EN/IEC 60529
IP41 on upper part EN/IEC 61800-5-1
Option card
Communication card APOGEE FLN
Communication card BACnet
Communication card LonWorks
Communication card METASYS N2
Complementary
power supply voltage limits
323…528 V
power supply frequency
50…60 Hz – 5…5 %
power supply frequency limits
47.5…63 Hz
Apparent power
23.2 kVA 380 V
maximum prospective line Isc
22 kA
maximum continuous output current
30.5 A 380 V
30.5 A 460 V
Maximum transient current
33.6 A 60 s
Speed drive output frequency
0.5…200 Hz
Nominal switching frequency
12 kHz
Switching frequency
12…16 kHz with derating factor
6…16 kHz adjustable
Speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
Torque accuracy
+/- 15 %
Regulation loop
Adjustable PI regulator
Motor slip compensation
Not available in voltage/frequency ratio motor control
Adjustable
Automatic whatever the load
diagnostic
For DC bus energized 1 LED (red)
Output voltage
<= power supply voltage insulation Electrical between power and control recommended type of cable for mounting in an enclosure With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.00 in² (2.5 mm²) / AWG 14 L1/R, L2/S, L3/T terminal 0.04 in² (25 mm²) / AWG 3 Tightening torque 5.31 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) 39.83 lbf.in (4.5 N.m), 40 lb.in L1/R, L2/S, L3/T) Supply Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection Analogue input number 2 Analogue input type VIA switch-configurable current 0...20 mA 242 Ohm 11 bits VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits Sampling duration F 2 ms +/- 0.5 ms discrete R 2 ms +/- 0.5 ms discrete RES 2 ms +/- 0.5 ms discrete VIA 2 ms +/- 0.5 ms analog VIB 2 ms +/- 0.5 ms analog Response time FLA, FLC 7 ms +/- 0.5 ms discrete FLB, FLC 7 ms +/- 0.5 ms discrete FM 2 ms +/- 0.5 ms analog RY, RC 7 ms +/- 0.5 ms discrete Accuracy +/- 1 % FM) for a temperature variation 60 °C +/- 0.6 % VIA) for a temperature variation 60 °C +/- 0.6 % VIB) for a temperature variation 60 °C Linearity error FM +/- 0.2 % output VIA +/- 0.15 % of maximum value input VIB +/- 0.15 % of maximum value input Analogue output number 1 Analogue output type FM switch-configurable current 0...20 mA 500 Ohm 10 bits FM switch-configurable voltage 0...10 V DC 470 Ohm 10 bits Discrete output number 2 Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles Configurable relay logic FLB, FLC) NC - 100000 cycles Configurable relay logic RY, RC) NO - 100000 cycles Minimum switching current 3 mA 24 V DC configurable relay logic Maximum switching current 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) Discrete input type F programmable 24 V DC level 1 PLC 3500 Ohm R programmable 24 V DC level 1 PLC 3500 Ohm RES programmable 24 V DC level 1 PLC 3500 Ohm Discrete input logic Negative logic (sink) F, R, RES), >= 16 V, <= 10 V Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Acceleration and deceleration ramps
Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Braking to standstill
By DC injection
Protection type
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Short-circuit between motor phases drive
Thermal power stage drive
Motor phase break motor
Thermal protection motor
With PTC probes motor
Against exceeding limit speed drive
Insulation resistance
>= 1 mOhm 500 V DC for 1 minute
Frequency resolution
Analog input 0.024/50 Hz
Display unit 0.1 Hz
Connector Type
1 RJ45
Physical interface
2-wire RS 485
Transmission frame
RTU
Transmission Rate
9600 bps or 19200 bps
Data format
8 bits, 1 stop, odd even or no configurable parity
Number of addresses
1…247
Communication Service
Monitoring inhibitable
Write multiple registers (16) 2 words maximum
Write single register (06)
Read device identification (43)
Time out setting from 0.1 to 100 s
Read holding registers (03) 2 words maximum
marking
CE
Operating position
Vertical +/- 10 degree
Height
12.97 in (329.5 mm)
Width
9.65 in (245 mm)
Depth
7.48 in (190 mm)
Product Weight
25.68 lb(US) (11.65 kg)
Environment
Noise level
54 dB 86/188/EEC
Dielectric strength
3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Electromagnetic compatibility
1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Voltage dips and interruptions immunity test IEC 61000-4-11
standards
EN 61800-3 environments 1 category C1
IEC 61800-5-1
IEC 61800-3 environments 2 category C2
IEC 61800-3 category C3
IEC 61800-3 category C2
IEC 61800-3 environments 2 category C3
EN 61800-5-1
EN 61800-3 environments 1 category C2
UL Type 1
EN 61800-3 environments 2 category C3
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 2 category C1
EN 55011 class A group 1
IEC 61800-3
EN 61800-3 environments 1 category C3
IEC 61800-3 environments 1 category C1
EN 61800-3 environments 2 category C2
EN 61800-3 category C3
IEC 61800-3 environments 1 category C3
EN 61800-3 category C2
EN 61800-3
EN 61800-3 environments 2 category C1
Product Certifications
C-tick
CSA
UL
NOM 117
Vibration resistance
1 gn 13…200 Hz)EN/IEC 60068-2-8
1.5 mm 3…13 Hz)EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms IEC 60068-2-27
Pollution degree
2 IEC 61800-5-1
Environmental characteristic
Classes 3C1 IEC 60721-3-3
Classes 3S2 IEC 60721-3-3
Relative humidity
5…95 % without condensation IEC 60068-2-3
5…95 % without dripping water IEC 60068-2-3
Ambient air temperature for operation
14…104 °F (-10…40 °C) without derating)
104…122 °F (40…50 °C) with derating factor)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Operating altitude
<= 6561.68 ft (2000 m) 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network Ordering and shipping details Category 22157-ATV212 1 - 25 HP 460 VOLT Discount Schedule CP4D GTIN 00785901701194 Removed from a control. 22.8 A 480 V 28.5 A 380 V Speed range 1…10 Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s Asynchronous motor control profile Constant voltage/frequency ratio Quadratic voltage/frequency ratio Constant voltage/frequency ratio with automatic IR compensation Energy saving ratio Current flux vector control (FVC) without speed feedback Communication Port Protocol Modbus Type of polarization No impedance IP degree of protection IP20 on upper part without blanking plate on cover EN/IEC 60529 IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1 IP21 EN/IEC 60529 IP21 EN/IEC 61800-5-1 IP41 on upper part EN/IEC 60529 IP41 on upper part EN/IEC 61800-5-1 Option card Communication card APOGEE FLN Communication card BACnet Communication card LonWorks Communication card METASYS N2 Complementary power supply voltage limits 323…528 V power supply frequency 50...60 Hz - 5...5 % power supply frequency limits 47.5…63 Hz Apparent power 23.2 kVA 380 V maximum prospective line Isc 22 kA maximum continuous output current 30.5 A 380 V 30.5 A 460 V Maximum transient current 33.6 A 60 s Speed drive output frequency 0.5…200 Hz Nominal switching frequency 12 kHz Switching frequency 12...16 kHz with derating factor 6...16 kHz adjustable Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Torque accuracy +/- 15 % Regulation loop Adjustable PI regulator Motor slip compensation Not available in voltage/frequency ratio motor control Adjustable Automatic whatever the load diagnostic For DC bus energized 1 LED (red) Output voltage <= power supply voltage insulation Electrical between power and control recommended type of cable for mounting in an enclosure With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.00 in² (2.5 mm²) / AWG 14 L1/R, L2/S, L3/T terminal 0.04 in² (25 mm²) / AWG 3 Tightening torque 5.31 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) 39.83 lbf.in (4.5 N.m), 40 lb.in L1/R, L2/S, L3/T) Supply Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection Analogue input number 2 Analogue input type VIA switch-configurable current 0...20 mA 242 Ohm 11 bits VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits Sampling duration F 2 ms +/- 0.5 ms discrete R 2 ms +/- 0.5 ms discrete RES 2 ms +/- 0.5 ms discrete VIA 2 ms +/- 0.5 ms analog VIB 2 ms +/- 0.5 ms analog Response time FLA, FLC 7 ms +/- 0.5 ms discrete FLB, FLC 7 ms +/- 0.5 ms discrete FM 2 ms +/- 0.5 ms analog RY, RC 7 ms +/- 0.5 ms discrete Accuracy +/- 1 % FM) for a temperature variation 60 °C +/- 0.6 % VIA) for a temperature variation 60 °C +/- 0.6 % VIB) for a temperature variation 60 °C Linearity error FM +/- 0.2 % output VIA +/- 0.15 % of maximum value input VIB +/- 0.15 % of maximum value input Analogue output number 1 Analogue output type FM switch-configurable current 0...20 mA 500 Ohm 10 bits FM switch-configurable voltage 0...10 V DC 470 Ohm 10 bits Discrete output number 2 Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles Configurable relay logic FLB, FLC) NC - 100000 cycles Configurable relay logic RY, RC) NO - 100000 cycles Minimum switching current 3 mA 24 V DC configurable relay logic Maximum switching current 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) Discrete input type F programmable 24 V DC level 1 PLC 3500 Ohm R programmable 24 V DC level 1 PLC 3500 Ohm RES programmable 24 V DC level 1 PLC 3500 Ohm Discrete input logic Negative logic (sink) F, R, RES), >= 16 V, <= 10 V Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Acceleration and deceleration ramps
Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Braking to standstill
By DC injection
Protection type
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Short-circuit between motor phases drive
Thermal power stage drive
Motor phase break motor
Thermal protection motor
With PTC probes motor
Against exceeding limit speed drive
Insulation resistance
>= 1 mOhm 500 V DC for 1 minute
Frequency resolution
Analog input 0.024/50 Hz
Display unit 0.1 Hz
Connector Type
1 RJ45
Physical interface
2-wire RS 485
Transmission frame
RTU
Transmission Rate
9600 bps or 19200 bps
Data format
8 bits, 1 stop, odd even or no configurable parity
Number of addresses
1…247
Communication Service
Monitoring inhibitable
Write multiple registers (16) 2 words maximum
Write single register (06)
Read device identification (43)
Time out setting from 0.1 to 100 s
Read holding registers (03) 2 words maximum
marking
CE
Operating position
Vertical +/- 10 degree
Height
12.97 in (329.5 mm)
Width
9.65 in (245 mm)
Depth
7.48 in (190 mm)
Product Weight
25.68 lb(US) (11.65 kg)
Environment
Noise level
54 dB 86/188/EEC
Dielectric strength
3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Electromagnetic compatibility
1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Voltage dips and interruptions immunity test IEC 61000-4-11
standards
EN 61800-3 environments 1 category C1
IEC 61800-5-1
IEC 61800-3 environments 2 category C2
IEC 61800-3 category C3
IEC 61800-3 category C2
IEC 61800-3 environments 2 category C3
EN 61800-5-1
EN 61800-3 environments 1 category C2
UL Type 1
EN 61800-3 environments 2 category C3
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 2 category C1
EN 55011 class A group 1
IEC 61800-3
EN 61800-3 environments 1 category C3
IEC 61800-3 environments 1 category C1
EN 61800-3 environments 2 category C2
EN 61800-3 category C3
IEC 61800-3 environments 1 category C3
EN 61800-3 category C2
EN 61800-3
EN 61800-3 environments 2 category C1
Product Certifications
C-tick
CSA
UL
NOM 117
Vibration resistance
1 gn 13…200 Hz)EN/IEC 60068-2-8
1.5 mm 3…13 Hz)EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms IEC 60068-2-27
Pollution degree
2 IEC 61800-5-1
Environmental characteristic
Classes 3C1 IEC 60721-3-3
Classes 3S2 IEC 60721-3-3
Relative humidity
5…95 % without condensation IEC 60068-2-3
5…95 % without dripping water IEC 60068-2-3
Ambient air temperature for operation
14…104 °F (-10…40 °C) without derating)
104…122 °F (40…50 °C) with derating factor)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Operating altitude
<= 6561.68 ft (2000 m) 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network Ordering and shipping details Category 22157-ATV212 1 - 25 HP 460 VOLT Discount Schedule CP4D GTIN 00785901701194 NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with Telemecanique or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners. We do our best to get all the information in this listing correct. If you see an error or have any questions, please contact us.

FAQ’s

Looking for a replacement Telemecanique ATV21HD15N4 with fast shipping?

NEO Surplus will ship in stock items the same day if purchased by 2pm ET, Monday – Friday.

What are the electrical specs for Telemecanique ATV21HD15N4?

Phase: {post_terms_pa_phase}

Hz: {post_terms_pa_hertz}

Input

Volts:

Amps:

Watts:

Output

Volts:

Amps:

Watts:

What is the HP rating for Telemecanique ATV21HD15N4?

HP:

NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with Telemecanique or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.

NEO Surplus buys surplus MRO items and then resells them on the secondary parts markets. 

We do our best to get all the information in this listing correct. If you have any questions or see an error, please contact us.

Make an offer on Telemecanique ATV21HD15N4

Current Price: $745.13

Request for Quote: Telemecanique ATV21HD15N4