Keyence GP-M010 Heavy Duty Digital Pressure Sensor New in Box
Brand: Keyence | Model: GP-M010 | Condition: New | NEO SKU: 11146-2
Original price was: $359.42.$296.03Current price is: $296.03.
1 in stock
Free Shipping on orders over $50.
*(Domestic only)
Need it fast? Next Day Air available at check out.
Same Day Handling on orders prior to 2pm Eastern Monday – Friday
1 in stock
NEO SKU: 11146-2 | Category: Proximity Sensors
Product Details for New: Keyence GP-M010 Heavy Duty Digital Pressure Sensor New in Box
Only logged in customers who have purchased this product may leave a review.
Keyence GP-M010 Heavy Duty Digital Pressure Sensor New in Box
Specifications:
SKU: 11146-2
Condition: New Surplus Manufacturer Packaging
Brand: Keyence
Model: GP-M010
Description: Heavy Duty Digital Pressure Sensor New in Box
Origin: China
Notes: From MFG:
Specifications
Model
GP-M010
Rated pressure
-14.5 to +145.0 PSI
(-0.1 to +1 MPa)
Possible display range
-30.5 to +161.0 PSI
(-0.210 to +1.110 MPa)
Zero-cut pressure value
±0.5% of F.S.
Burst pressure
2175 PSI (15 MPa)
Display resolution
kPa
1
MPa
0.001
PSI
0.1
bar
0.01
kgf/cm2
Fluid type
Gas or liquid that will not corrode the liquid contact part
Type of pressure
Gage pressure
Precision
±1.0% of F.S. or less*1
Repeatability
±0.3% of F.S. or less*2
Temperature characteristics
±0.6% of F.S./10°C 50°F
Connection port
G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)
Box rotation angle
Maximum 330°
Medium temperature
-20 to +100°C -4°F to +212°F (no freezing/condensation)*3
Power voltage
10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS
Current consumption
50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4
Display method
4 column, digital LED, red/Vertical inversion display possible
Operation display light
Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)
Hysteresis
During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)
Response
Control output
Selectable from 3 to 5000 ms
Analog output
As above + 2 ms (90% response)
Output
Output 1 control output
NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable
Output 2
replacement type
Control output
Analog output
4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5
Environmental resistance
Enclosure rating
IP67
Pressure resistance
4 MPa (40 bar)
Ambient temperature
-20 to +80 °C -4 to 176 °F (No freezing and no condensation)
Relative humidity
35 to 85 % RH (No condensation)
Vibration resistance
IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)
Shock resistance
IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)
Material
properties
Wetted part
Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM
Other parts
Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.
Applicable cable
M12 connector 4 pin
Weight
Approx. 150 g
NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with Keyence or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.
We do our best to get all the information in this listing correct. If you see an error or have any questions, please contact us.
Additional information
Weight | 3 lbs |
---|---|
Dimensions | 8 × 8 × 7 in |
Brand | Keyence |
Model | GP-M010 |
Origin | China |
Condition | New |
Body Notes | 2 hours each in the X, 3 times for each of X, Air hole: PTFE, and NPT male 1/4 option adapters are available.) Box rotation angle Maximum 330° Medium temperature -20 to +100°C -4°F to +212°F (no freezing/condensation)*3 Power voltage 10-30 VDC, and Z axis) Shock resistance IEC60068-2-27 50G (11 ms, Class 2 or LPS Current consumption 50 mA or less (when 24 V: 32 mA or less, Diaphragm pressure port: Al2O3 (Alumina), digital LED, G female 1/4, Housing plastic portion: PPSU, Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable Output 2 replacement type Control output Analog output 4-20 mA, nickel-plated brass. Applicable cable M12 connector 4 pin Weight Approx. 150 g, NPT male 1/8, O ring: FKM Other parts Housing metal portion: SUS304, R male 1/4, R male 3/8, red/Vertical inversion display possible Operation display light Operation indicator (output 1) (orange), Ripple (P-P): 10% max, SUS303, when 12 V: 48 mA or less. Not including load)*4 Display method 4 column, Y, Y and Z direction) Material properties Wetted part Pressure port: SUSXM7 |
Related Products
FAQ’s
Looking for a replacement Keyence GP-M010 with fast shipping?
NEO Surplus will ship in stock items the same day if purchased by 2pm ET, Monday – Friday.
Can I ship using my carrier account?
Do you offer Blind Shipping?
Other Questions?
Contact us if you have more questions.NEO Surplus is not an authorized distributor, representative, reseller, or affiliated with Keyence or any manufacturer, brand, or product. Items being sold are not covered under any manufacturer warranty. All trademarks, brand names and brands appearing herein are the property of their respective owners.
NEO Surplus buys surplus MRO items and then resells them on the secondary parts markets.
We do our best to get all the information in this listing correct. If you have any questions or see an error, please contact us.
Reviews
There are no reviews yet.
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.